Turnstiles & Gates

Turnstile gatesChoose the passage.
Then the gate.

These turnstile gates cover tripod turnstiles, swing gates, flap barriers and full-height turnstiles. Start with the way people move through your entrance. Choose a gate structure, compare the models and plan the cabinet configuration around your access workflow.

Find your starting point

Five structures.
A clearer choice.

Choose by passage structure first. Each model page covers the supplied hardware, configuration choices and installation questions.

Explore the hardware

AB interlocking gates

1 models · Page 1 of 1

Plan the passage sequence, sensors, supervision and complete footprint.

Showing 1–1 of 1. Model names use the single-mechanism reference where applicable; a cabinet is not a complete lane.

Compare the structures

Plan the fit.
Review the workflow.

Gate structures and project planning
StructureBarrier movementPlanning focus
AB interlocking gatesTwo sequential barrier stagesInterlock sequence, chamber, sensing and supervision
Swing gatesSwinging barrier leavesClear passage, cabinet arrangement and reader placement
Flap barriersRetracting flap barriersBarrier clearance, lane arrangement and sensor response
Tripod turnstilesThree-arm rotating mechanismArm clearance, passage sequence and separate accessible route
Full-height turnstilesFull-height rotating barrierComplete footprint, rotation clearance and emergency route

Cabinet size is different from clear passage width and the complete installed footprint. Request the approved installation drawing before preparing the floor.

Bring the entrance together

Plan the cabinets.
Then the passage.

For compatible swing and flap systems, two outer single-mechanism cabinets form one lane. Adding a matching double-mechanism cabinet between them can form two lanes. Confirm the matching assemblies and project drawing; tripod and full-height structures use their own layouts.

  • Entrance width, lane count and accessible route
  • Credential workflow, controller and required signals
  • Floor fixing, power, cable route and emergency behaviour
Discuss the entrance layout
FC24EAB interlocking gate portal with transparent barriers with a floor base and overhead column

FC24EAB · supplied portal rendering from the Tencent product sheet; final equipment and configuration require confirmation.

Before you request a quotation

What should a turnstile quotation include?

Compare the complete entrance scope: cabinets, passage layout, readers, control equipment and installation work. A cabinet price alone does not describe a working access-control lane.

Prepare your project brief

  • Entrance drawing: available width, clear passage, lane count and a separate accessible or emergency route where needed.
  • Model and cabinet arrangement: single- or double-mechanism cabinets, direction of travel and the selected mechanism option.
  • Credential and platform: QR, card or face workflow, existing reader/controller models and who makes the access decision.
  • Connections: required control signals, power, cable routes and the approved wiring and installation drawings.
  • Acceptance checks: denied access, repeated credentials, loss of power or network, passage feedback and recovery.
  • Delivery scope: quantity, deployment market, site conditions, installer responsibilities and the documents required for the project.
Can we connect our current QR reader or face terminal?

The reader output and gate-controller input must match. Confirm the electrical interface, signal timing, direction and available feedback with both wiring references. A reader appearing in the Feocey catalogue does not by itself establish a tested pairing. Review the integration guide and request the references for the exact models and firmware.

Does a gate opening command prove that someone passed through?

No. A command acknowledgement, barrier movement and actual passage are separate events. Confirm which sensors and feedback the selected configuration provides, and which events your platform needs. Test the agreed behaviour on the sample system before deployment.

Before you choose a gate.

Which turnstile gate helps prevent tailgating?

Review FC24EAB when the entrance needs a two-gate interlock. The inner gate opens only when exactly one person is in the space between the two gates. Confirm the sensors, supervision and passage order for the installation.

When should you choose a full-height turnstile?

Choose a full-height turnstile when the entrance needs an enclosed rotating barrier and people should pass through one at a time. It is a different structure from a swing gate, a flap barrier or the FC24EAB interlock. Confirm the footprint, the adjoining accessible route and the site conditions for the project.

How do we choose a gate structure?

Start with the passage workflow, available space and users. Swing gates use swinging barrier leaves; flap gates retract their barriers; tripod turnstiles use a three-arm mechanism; full-height turnstiles use a rotating barrier; AB gates coordinate two sequential stages. Review the lane layout, supervision, accessible route and emergency behaviour with the project team.

Does a single-mechanism cabinet mean a complete single lane?

For compatible swing and flap systems, a single-mechanism cabinet controls one side of a lane. Two matching outer cabinets form one lane; adding a compatible double-mechanism cabinet between them can form two lanes. Single and double mechanisms describe cabinet configurations, not complete lane quantities. Tripod, full-height and AB gates use their own arrangements. Confirm the final quantities and footprint on the project drawing.

Is cabinet size the same as clear passage width?

No. Cabinet size, clear passage width and the complete installed footprint describe different measurements. Confirm the cabinet arrangement, arm or barrier movement, accessible route, fixing pattern and service clearance using the approved project drawing.

Are the pictured readers and face terminals included?

The pictures illustrate possible access configurations. Confirm the gate, readers, terminals, controllers, software and quantities in the order. Match the credential output, gate input, control protocol and power arrangement before integration.

What should we provide to request a gate layout?

Send the entrance width, planned lanes, expected passage workflow, reader or controller, floor construction, power and cable route. Include the accessible route and required emergency behaviour. Ask for the model-specific installation and wiring references before preparing the site.

Interested in this product?

Tell us the model and quantity.