Turnstiles & Gates

FC-FFHTLSFJT

Full-height turnstile

Full-height turnstile.

A full-height turnstile for supervised pedestrian checkpoints. Select the material and mechanism configuration, then plan the complete footprint and adjoining accessible route.

  • Full-height rotor enclosure
  • Material and mechanism options
  • Supervised checkpoint planning

Choose your configuration

SUS304 electric configuration. Confirm the mechanism, component grades and final order drawing.

Your choice is included in the enquiry. Our team will confirm the supplied configuration and layout.

FC-FFHTLSFJT full-height turnstile with a curved enclosure and rotating arm assembly
FC-FFHTLSFJT · Supplied product view. Confirm the selected finish, mechanism and assembly.

Full-height turnstile.
Plan your entrance.

A full-height turnstile for supervised pedestrian checkpoints. Select the material and mechanism configuration, then plan the complete footprint and adjoining accessible route.

Structure
Full-height turnstiles
Configuration
Select the mechanism
Installation
Confirm the order drawing

Product views show possible cabinet and lane arrangements. Readers and terminals are selected separately; final quantities and dimensions follow the confirmed order drawing.

Technical specifications.

FC-FFHTLSFJT · SUS304 electric

Parameters describe the listed model configuration. Confirm the selected mechanism, final cabinet and lane dimensions, controller and order drawing. Throughput varies with access checks and passage conditions.

FC-FFHTLSFJT specifications
ConfigurationSUS304 electric
StructureFull-height turnstile
Cabinet dimensions1630 × 1500 × 2250 mm
Passage widthUp to 550 mm
Cabinet / frame materialSUS304 stainless-steel cabinet and rotor arms, standard configuration
Input voltage110–220 V · 50 Hz
More specifications
FC-FFHTLSFJT additional specifications
Specified throughput20–60 persons / minute; actual flow depends on credential checks and passage conditions
Working environmentIndoor
Operating temperature−25°C to 70°C
FC-FFHTLSFJT full-height turnstile with a curved enclosure and rotating arm assembly
FC-FFHTLSFJT · Supplied product view. Confirm the selected finish, mechanism and assembly.

Match the gate
to the entrance.

Factory, construction-site, attraction and venue checkpoints. The listed standard environment is indoor; confirm exposure and installation requirements for each project.

Product views show possible cabinet and lane arrangements. Readers and terminals are selected separately; final quantities and dimensions follow the confirmed order drawing.

FC-FFHTLSFJT full-height turnstile enclosure and rotating arms viewed from the front
FC-FFHTLSFJT · Supplied product view. Confirm the selected finish, mechanism and assembly.

Plan the credential check.
Confirm the connection.

Choose the reader and access controller for the required credential workflow, then confirm the gate input, signal timing, wiring and controller protocol. Commission the passage sequence, sensor response and emergency behaviour with the actual configuration.

Reader compatibility depends on the selected controller and signals. Credential readers, software and gate hardware are specified separately.

FC-FFHTLSFJT full-height rotating turnstile assembly viewed from above
FC-FFHTLSFJT · Supplied product view. Confirm the selected finish, mechanism and assembly.

Review the cabinet.
Plan the layout.

Use the additional supplied view to review the appearance and cabinet arrangement. Match the selected mechanism and complete entrance footprint to the approved order drawing.

Product views show possible cabinet and lane arrangements. Readers and terminals are selected separately; final quantities and dimensions follow the confirmed order drawing.

FC-FFHTLSFJT full-height rotating turnstile assembly viewed from above
FC-FFHTLSFJT · Supplied product view. Confirm the selected finish, mechanism and assembly.

Measure the entrance.
Confirm the drawing.

Provide the entrance width, lane count, user requirements, floor construction, cable routes and service clearance. Obtain the approved model and configuration drawing before preparing fixing holes or wiring. Check the separate accessible route and the project’s emergency requirements.

  • Confirm the selected mechanism’s cabinet dimensions and passage width.
  • Review its electrical supply, controller and required signals.
  • Confirm cabinet count, reader mounting, cable routes and service clearance.
Request documents for FC-FFHTLSFJT

The product view is not a drilling template or a certified site plan. A matching operating manual and installation drawing must be requested for the supplied configuration.

Product resources.

Manuals and integration support for FC-FFHTLSFJT.

Documents for FC-FFHTLSFJT →

Request the manual, dimension drawing and integration reference for your FC-FFHTLSFJT configuration.

Request documents for FC-FFHTLSFJT

Your questions, answered.

How do we choose a gate structure?

Start with the passage workflow, available space and users. Swing gates use swinging barrier leaves; flap gates retract their barriers; tripod turnstiles use a three-arm mechanism; full-height turnstiles use a rotating barrier; AB gates coordinate two sequential stages. Review the lane layout, supervision, accessible route and emergency behaviour with the project team.

Does a single-mechanism cabinet mean a complete single lane?

For compatible swing and flap systems, a single-mechanism cabinet controls one side of a lane. Two matching outer cabinets form one lane; adding a compatible double-mechanism cabinet between them can form two lanes. Single and double mechanisms describe cabinet configurations, not complete lane quantities. Tripod, full-height and AB gates use their own arrangements. Confirm the final quantities and footprint on the project drawing.

Is cabinet size the same as clear passage width?

No. Cabinet size, clear passage width and the complete installed footprint describe different measurements. Confirm the cabinet arrangement, arm or barrier movement, accessible route, fixing pattern and service clearance using the approved project drawing.

Are the pictured readers and face terminals included?

The pictures illustrate possible access configurations. Confirm the gate, readers, terminals, controllers, software and quantities in the order. Match the credential output, gate input, control protocol and power arrangement before integration.